Circular Dichroism Field Guide
Chiroptical spectroscopy · graduate primer

Circular Dichroism

A chiral sample absorbs left- and right-circularly polarized light by slightly different amounts. That difference, usually 10−3–10−5 of the total absorbance, reports on absolute configuration, secondary structure, folding and binding.

$$\Delta A(\lambda) = A_L(\lambda) - A_R(\lambda) = \Delta\varepsilon(\lambda)\,c\,\ell$$
ECD · 160–800 nmtypical ΔA ≈ 10⁻⁴θ(mdeg) = 32 980 · ΔA
Electric-field vector, viewed facing the source

Linear light is the sum of equal L and R components. Unequal absorption makes the sum elliptical (CD). Unequal refractive index rotates the ellipse (optical rotation, ORD). Real ΔA values are about a thousand times smaller than shown.

Quantities and conversions

The equations you will actually use

CD is reported in at least five interconvertible units. Most errors in the literature come from mixing them up or from a wrong concentration. The highlighted cards are the ones to memorize.

Definition

Differential absorbance

$$\Delta A = A_L - A_R = (\varepsilon_L-\varepsilon_R)\,c\,\ell = \Delta\varepsilon\, c\,\ell$$

\(\Delta\varepsilon\) in M⁻¹ cm⁻¹, \(c\) in mol L⁻¹, \(\ell\) in cm. Beer–Lambert applied separately to each circular component.

Instrument output

Ellipticity

$$\tan\theta = \frac{E_R - E_L}{E_R + E_L}, \qquad \theta\,[\text{deg}] = \frac{\ln 10}{4}\cdot\frac{180}{\pi}\,\Delta A \approx 32.98\,\Delta A$$

Most spectropolarimeters display θ in millidegrees: \(\theta_{\text{mdeg}} = 32\,980\,\Delta A\).

Proteins

Mean residue ellipticity

$$[\theta]_{\text{MRW}} = \frac{\theta_{\text{mdeg}}\cdot \text{MRW}}{10\,\ell\, c_{\text{mg/mL}}}, \qquad \text{MRW} = \frac{M}{N-1}$$

Units deg cm² dmol⁻¹. \(N-1\) counts peptide bonds, the far-UV chromophores. Use this to compare proteins of different size.

Small molecules

Molar ellipticity

$$[\theta] = \frac{100\,\theta_{\text{deg}}}{c\,\ell} = 3298.2\,\Delta\varepsilon$$

\(c\) in mol L⁻¹, \(\ell\) in cm; units deg cm² dmol⁻¹. The factor 3298.2 = 100 · ln10 · 180 / (4π).

Dimensionless

Anisotropy (Kuhn g-factor)

$$g = \frac{\Delta\varepsilon}{\varepsilon} = \frac{\Delta A}{A} \approx \frac{4R}{D}$$

Electric-dipole-allowed π→π*: \(g\sim10^{-4}\text{–}10^{-3}\). Magnetic-dipole-allowed n→π* (ketones): \(g\sim10^{-2}\). Also used for CPL (\(g_{\text{lum}}\)).

Theory ↔ experiment

Rotational strength (Rosenfeld)

$$R_{0a} = \operatorname{Im}\!\left(\langle 0|\hat{\boldsymbol\mu}|a\rangle\cdot\langle a|\hat{\boldsymbol m}|0\rangle\right) = |\boldsymbol\mu_{0a}||\boldsymbol m_{a0}|\cos\xi$$

A transition is CD-active only if its electric (\(\boldsymbol\mu\)) and magnetic (\(\boldsymbol m\)) transition dipoles are not perpendicular. In an achiral molecule \(R=0\) by symmetry.

From a measured band

Integrated rotational & dipole strength

$$R = 2.296\times10^{-39}\!\int\!\frac{\Delta\varepsilon(\lambda)}{\lambda}\,d\lambda,\quad D = 9.184\times10^{-39}\!\int\!\frac{\varepsilon(\lambda)}{\lambda}\,d\lambda$$

Units esu² cm² (1 DBM = 0.9274×10⁻³⁸ esu² cm²). Compare R with TDDFT output after fitting the band.

Band shape

Gaussian Cotton effect

$$\Delta\varepsilon(\tilde\nu) = \frac{\tilde\nu\, R}{2.296\times10^{-39}\sqrt{\pi}\,\Delta\tilde\nu}\exp\!\left[-\left(\frac{\tilde\nu-\tilde\nu_0}{\Delta\tilde\nu}\right)^{2}\right]$$

How computed \(R\) values are broadened into a spectrum; \(\Delta\tilde\nu\) is the half-width at 1/e.

CD ↔ ORD

Kramers–Kronig transform

$$[\phi](\lambda) = \frac{2}{\pi}\int_0^{\infty}[\theta](\lambda')\,\frac{\lambda'}{\lambda^{2}-\lambda'^{2}}\,d\lambda'$$

Absorption (CD) and dispersion (ORD) are two faces of one complex response. A single CD band produces an anomalous, sign-changing ORD curve centered on it.

Coupled chromophores

Exciton coupling (point dipole)

$$V_{12} = \frac{\boldsymbol\mu_1\!\cdot\!\boldsymbol\mu_2}{R_{12}^{3}} - \frac{3(\boldsymbol\mu_1\!\cdot\!\mathbf R_{12})(\boldsymbol\mu_2\!\cdot\!\mathbf R_{12})}{R_{12}^{5}}$$
$$R_{\pm} = \pm\frac{\pi\tilde\nu_0}{2}\,\mathbf R_{12}\cdot(\boldsymbol\mu_1\times\boldsymbol\mu_2)$$

Two states split by \(2V_{12}\) with equal and opposite rotational strengths give a bisignate couplet. Sign follows the helicity of the dipole pair (sign convention depends on how \(\mathbf R_{12}\) is defined). Try it below.

Helix content

Two-state helicity from [θ]₂₂₂

$$f_H = \frac{[\theta]_{222}-[\theta]_C}{[\theta]_H-[\theta]_C}$$
$$[\theta]_H = -40\,000\left(1-\tfrac{2.5}{n}\right)+100\,T,\quad [\theta]_C = 640-45\,T$$

Luo & Baldwin (1997), \(T\) in °C, \(n\) residues. Suitable for helical peptides; use full deconvolution for globular proteins.

Signal-to-noise

Optimal absorbance

$$\frac{S}{N}\propto \Delta A\cdot 10^{-A/2}\ \Rightarrow\ A_{\text{opt}} = \frac{2}{\ln 10}\approx 0.87$$

Aim for total absorbance (sample + buffer + cell) near 0.8–1.0 at the wavelength of interest. Above ~2 the photomultiplier HT voltage rises and data become unreliable.

Where the signal lives

Spectral regions and their chromophores

Each window reports on a different structural level. Hover or tap a band for detail.

Far-UV (190–250 nm): peptide backbone n→π* (~220 nm) and π→π* (~190, 208 nm) transitions. Secondary structure.

Far-UV · secondary structure

Build a protein spectrum from its parts

To a first approximation a far-UV spectrum is a linear combination of basis spectra: \(\;[\theta](\lambda) = \sum_k f_k\,[\theta]_k(\lambda)\). Deconvolution algorithms invert this against reference sets of proteins with known structures. The basis curves here are idealized Gaussian models for teaching, not a reference set.

Compositeα-helixβ-sheetDisordered / PPII

Signatures to recognize: α-helix gives a strong positive band near 192 nm and two minima at 208 and 222 nm. β-sheet gives a single minimum near 215–218 nm and a weaker positive band near 195 nm. Disordered chains give a deep minimum near 198 nm. A [θ]222/[θ]208 ratio above ~1.0 can indicate interacting helices such as coiled coils.

Stereochemistry · exciton chirality method

Two chromophores, one couplet

When two strong π→π* chromophores sit close together in space, their excited states mix. The result is two exciton states split by \(2V_{12}\) with opposite rotational strengths. The sign of the resulting bisignate Cotton effect gives the absolute sense of twist between the chromophores (Harada–Nakanishi). The model below uses two dipoles perpendicular to the connecting axis, twisted by dihedral angle α.

Δε, sumLower exciton stateUpper exciton stateUV absorption (scaled)
Chirality

The couplet vanishes at α = 0° or 180° (no chirality) and at 90° (no coupling, so the two bands cancel). Coupling falls off as \(1/R^{3}\), so the amplitude drops quickly with distance. Here \(V_{12}\,[\text{cm}^{-1}] = 5.04\,\kappa\,\mu_1\mu_2/R^{3}\) with μ in debye and R in nm.

How ΔA ≈ 10⁻⁵ is measured

Inside a spectropolarimeter

Modern instruments do not measure AL and AR separately. A photoelastic modulator switches the beam between L and R at ~50 kHz, and a lock-in amplifier extracts the tiny AC component riding on the DC transmitted intensity.

Xe arc lamp150–450 W, N₂ purged Double prism mono.quartz, linear polarizer PEMδ(t) = δ₀ sin ωt, ≈50 kHz Sample cell0.01–1 cm quartz PMTHT voltage servo Lock-in at ωV_ac / V_dc → θ linearLRalternating DC level held constant by HT feedback
Detected signal
$$\frac{V_{ac}}{V_{dc}} = \frac{I_R - I_L}{I_R+I_L}\cdot 2J_1(\delta_0) = \tanh\!\left(\frac{\ln10}{2}\Delta A\right)2J_1(\delta_0) \approx 1.1513\,\Delta A\cdot 2J_1(\delta_0)$$

\(J_1\) is the first-order Bessel function; the PEM amplitude \(\delta_0\) is tracked with wavelength (quarter-wave retardation).

Calibration
$$\text{CSA: } [\theta]_{290.5} = +7\,910,\quad \frac{[\theta]_{192.5}}{[\theta]_{290.5}} \approx -2.0$$

Ammonium d-10-camphorsulfonate checks both the magnitude scale and the far-UV response. Check it regularly and after lamp changes.

Bench practice

Getting data a reviewer will trust

Most bad CD spectra come from absorbing buffers, wrong concentrations or saturated detectors, not from the instrument.

Buffer & sample

  • Good below 200 nm: 10 mM sodium phosphate, NaF or KF, borate, low % TFE.
  • Avoid in far-UV: Cl⁻ (NaCl, HCl, Tris-HCl, GdmCl), imidazole, DTT, HEPES/MES at high concentration, DMSO, EDTA excess.
  • Swap NaCl for NaF or Na₂SO₄ at the same ionic strength.
  • Filter or centrifuge: aggregates scatter and distort the spectrum through differential scattering and absorption flattening.
  • Far-UV: 0.1–0.5 mg mL⁻¹ in 0.1 cm cells, or ~1 mg mL⁻¹ in 0.01 cm demountable cells.

Acquisition

  • Purge with N₂ for ≥15 min before switching on the lamp (O₂ forms ozone and absorbs below 200 nm).
  • Record the HT/dynode voltage with every spectrum. Truncate data where it exceeds the manufacturer limit (often ~600–700 V).
  • Bandwidth 1 nm, step 0.5–1 nm, digital integration time × scans chosen for S/N; average 3–8 scans.
  • Measure buffer in the same cell and subtract; zero the spectrum at 250–260 nm for far-UV only if justified.
  • Keep temperature fixed with a Peltier holder; report it.

Concentration & reporting

  • Concentration error propagates 1:1 into [θ] and into structure fractions. Use A280 with a computed ε, or amino-acid analysis for proteins lacking Trp and Tyr.
  • Calibrate path length of short cells by interferometry or with a standard.
  • Report units, MRW, path length, concentration method, instrument, and HT.
  • Deposit spectra in the Protein Circular Dichroism Data Bank (PCDDB).
Tool

Units converter

Convert the instrument's raw millidegrees into the units a paper needs. The example values describe a 0.2 mg mL⁻¹ lysozyme-sized protein in a 1 mm cell.

Stability · two-state unfolding

Thermal melts at 222 nm

Following [θ]222 while heating gives a denaturation curve. For a reversible two-state transition the fraction folded follows from the Gibbs–Helmholtz equation. Check reversibility by cooling and re-scanning before fitting.

[θ]₂₂₂ΔGunf(T), right axis
$$\Delta G(T)=\Delta H_m\!\left(1-\frac{T}{T_m}\right)-\Delta C_p\!\left[(T_m-T)+T\ln\frac{T}{T_m}\right]$$
$$f_N = \frac{1}{1+e^{-\Delta G/RT}},\quad [\theta] = f_N[\theta]_N + (1-f_N)[\theta]_U$$

A large ΔCp curves the stability profile and can expose cold denaturation. In practice, fit sloping native and unfolded baselines as well. The van 't Hoff ΔH from CD equals the calorimetric ΔH only for a true two-state process.

Analysis software

Deconvolution and interpretation tools

ToolApproachUse it for
DichroWebWeb server running CONTIN-LL, SELCON3, CDSSTR, K2D with reference sets (SP175, SMP180 for membrane proteins)Standard secondary-structure estimation with goodness-of-fit (NRMSD)
BeStSelEight structure classes including parallel/antiparallel and β-sheet twistβ-rich proteins, amyloid; fold recognition from CD
CDSSTRVariable-selection SVD over reference proteinsRobust general estimates; needs data to ~190 nm or lower
K2D3Nearest-neighbour on theoretical spectraQuick α/β estimate from 190–240 nm data
PDB2CD / DichroCalcPredict CD from atomic coordinatesChecking a model or MD ensemble against experiment
TDDFT (Gaussian, ORCA, Turbomole)Conformer search → Boltzmann-weighted computed R and ECDAbsolute configuration of small molecules and natural products

Expect roughly ±5–10% accuracy for helix content, worse for β-sheet and turns. Report which algorithm and reference set you used, and the wavelength cut-off.

The chiroptical family

Related methods

MethodMeasuresRangeStrength
ECDΔA for electronic transitions180–800 nmFast, low sample need, secondary structure
SRCDECD with synchrotron light≥ 160 nmMore transitions, better β/turn resolution, high-throughput
VCDΔA for vibrational transitions800–4000 cm⁻¹Absolute configuration without a chromophore; g ≈ 10⁻⁵
ROARaman intensity difference for R vs LRaman shiftAqueous solutions, backbone and side-chain detail
ORDOptical rotation vs wavelengthUV–visKK-related to CD; works away from absorption bands
MCDCD induced by a magnetic field (A, B, C terms)UV–NIRElectronic structure of metal centres, even in achiral samples
CPLDifferential emission of L vs R lightemissionChirality of excited states, glum
LDA∥ − A⊥ for oriented samplesUV–visOrientation of transitions; a CD artefact in oriented films
Further reading

Where to go next

  1. Kelly, S. M., Jess, T. J. & Price, N. C. How to study proteins by circular dichroism. Biochim. Biophys. Acta 1751, 119–139 (2005).
  2. Greenfield, N. J. Using circular dichroism spectra to estimate protein secondary structure. Nat. Protoc. 1, 2876–2890 (2006).
  3. Miles, A. J., Janes, R. W. & Wallace, B. A. Tools and methods for circular dichroism spectroscopy of proteins: a tutorial review. Chem. Soc. Rev. 50, 8400–8413 (2021).
  4. Berova, N., Nakanishi, K. & Woody, R. W. (eds) Circular Dichroism: Principles and Applications, 2nd edn (Wiley-VCH, 2000).
  5. Berova, N., Polavarapu, P. L., Nakanishi, K. & Woody, R. W. (eds) Comprehensive Chiroptical Spectroscopy, Vols 1–2 (Wiley, 2012).
  6. Harada, N. & Nakanishi, K. Circular Dichroic Spectroscopy: Exciton Coupling in Organic Stereochemistry (University Science Books, 1983).
  7. Micsonai, A. et al. Accurate secondary structure prediction and fold recognition for circular dichroism spectroscopy. PNAS 112, E3095–E3103 (2015).
  8. Whitmore, L. & Wallace, B. A. Protein secondary structure analyses from circular dichroism spectroscopy: methods and reference databases. Biopolymers 89, 392–400 (2008).
  9. Luo, P. & Baldwin, R. L. Mechanism of helix induction by trifluoroethanol. Biochemistry 36, 8413–8421 (1997).
  10. Barron, L. D. Molecular Light Scattering and Optical Activity, 2nd edn (Cambridge University Press, 2004).